Printronix ThermaLine Series Printer User Manual


 
2–6
Configuration
Auto Uppercase
This parameter enables the printer to print text in all uppercase.
Disable. The default. The printer will print text in upper- and lowercase.
Enable. The printer will print text in uppercase only.
Skip Command Prefix
This parameter determines if a data string before an IGP/PGL command will
be ignored.
Disable. The printer will print any data before an IGP/PGL command.
Enable. The default. The printer ignores all text before an IGP/PGL
command.
Power On IGP/PGL
You can set the IGP/PGL feature so that it is enabled or disabled when the
printer is powered on.
Disable. The IGP/PGL is disabled when the printer is powered on. (The
IGP/PGL feature is initialized to the Quiet mode.)
Enable. The default. The IGP/PGL is enabled when the printer is powered
on. (The IGP/PGL feature is initialized in the Normal mode.)
Extended Execute Copy
Disable. The default. Dynamic data, overlay data, etc. are not allowed if the
optional Form Count parameter (number of forms to print) is specified as
part of the Execute command. (This setting is IGP
100 compatible.)
Enable. Dynamic data, overlay data, etc. are allowed within a form in which
the Form Count parameter is specified in the Execute command. In this case,
the exact same form (with identical dynamic data, etc.) is printed for
whatever the Form Count is. However, incremental data is not incremented
since the page that is printing is exactly the same. Also, each form is printed
on a separate page.