Printronix ThermaLine Series Printer User Manual


 
Commands4–34
Configuration
Purpose Places the IGP/PGL in the Configuration mode, where changes to any or all
of the IGP/PGL configuration parameters via software control can be made
instead of from the printer control panel.
Mode NORMAL
NOTE: A separate line is required for the CONFIG command, the parameters and
values, and the END command.
Format (cc)CONFIG
parameter;value
END
(cc) The Special Function Control Character (SFCC).
CONFIG The Configuration command; enter CONFIG.
parameter;value The parameter for which a configuration change is
desired, and the value associated with that parameter.
The available parameters are listed in Table 4–2, and
the associated values are shown in Table 1–4 on page
1–13.
END Terminates the CONFIG command; enter END.
Table 4–2. CONFIG Command Parameters
CARRIAGE RETURN DEF
LINE FEED DEF
AUT
O
WRAP
SFCC
SLEW RANGE
RESET
AUTO EJECT
TOP/BOTT
OM MARGIN
LEFT
MARGIN
UPPERCASE
SKIP PREFIX