Printronix ThermaLine Series Printer User Manual


 
Commands4–92
TIFF Logo
Purpose Places the IGP/PGL in the Create Logo mode, where logos can be defined
using a Tagged Image File Format (TIFF).
Mode NORMAL
Format (cc)(LOGO;logoname;TIFF[;DISK](T)
<TIFF raster data> (cc) RASTEREND [T]
END(T)
(cc) The Special Function Control Character.
LOGO The Logo command; enter LOGO.
logoname Enter a maximum of 12 alphanumeric characters for
the name of the logo. (Refer to page 4–5 for a list of
allowable Logo Name characters.) All future
references to this logo (Delete Logo or Logo Call
commands) must use this name. If a logo is defined
with the same name as a logo already existing in
memory, the newly defined logo will replace the
existing logo.
TIFF The command denoting raster data in TIFF format;
enter TIFF.
DISK Optional parameter to store the logo in the IGP/PGL
external memory module. Enter DISK.
T Line terminator.
TIFF raster data Scanned data in TIFF format; data must be black and
white. Grey scales or color TIFF files are currently not
supported. Both uncompressed and packed–bits
compression formats are supported.
(cc) The Special Function Control Character.
RASTEREND Denotes the end of the TIFF raster data. Enter
RASTEREND.
END Terminates the TIFF logo; enter END.