Printronix ThermaLine Series Printer User Manual


 
5–95Bar Codes
ASPECT;h:w Optional parameter for specifying the symbol
height–to–width ratio where h is the height and w is
the width, both expressed as integers. The default is
1:2. Parameters Hn, Wn, Rn, or Cn cannot be entered if
this parameter is used.
Rn Optional parameter that specifies the number of rows
the symbol will have. Enter R; followed by the number
of rows in the range of 3 to 90 in multiples of 3.
Parameters Hn, Wn, Cn or ASPECT can not be entered
if this parameter is used.
Cn Optional parameter that specifies the number of
columns the symbol will have. Enter C; followed by
the number of columns in the range of 1 to 90.
Parameters Hn, Wn, Rn or ASPECT can not be entered
if this parameter is used.
Sn Optional parameter that specifies the security level.
Enter S; followed by the security level in the range of
0–8. The default is 2.
BFn;L Optional parameters for assigning a dynamic bar code
data field location on a form and for designating the
length of the data field. With these parameters, the
actual data for the bar code data field is dynamically
provided during the Execute Form Mode; the data is
not specified during the Create Form Mode. To use this
field, perform the following steps:
a. Enter BF.
b. Replace n with a number ranging from 1 to 255
to identify the bar code field. The SR and SC
parameters specify the exact location of the bar
code field identified by n.
c. Replace L with a number equaling the total
number of characters in the field. (The actual
data provided dynamically during the Execute
Form Mode can be less than L.)