Psion Teklogix 7530 G2 Laptop User Manual


 
Psion Teklogix 7530 G2 Hand-Held Computer User Manual 139
Chapter 5: Configuration
Protocol Tab
Cellular Radio Address
Auto Radio Address
If Auto radio address is enabled, the 7530 G2 requests an automatically assigned
radio address. Manual radio address is displayed in grey text indicating that it
cannot be accessed.
Manual Radio Address
The value entered in the Manual Radio Address parameter is used to identify
the 7530 G2 over the radio link. A unique value from 1 to 3840 must be assigned for
each unit.
Note: This parameter is set to ‘0’ (an out-of-range value) by default to block
radio communication when the unit is initially powered up. This prevents
several new hand-helds from attempting to communicate with the same
default terminal number at initial power up. Once the default value is
changed, it cannot be set back to ‘0’.
Polling
The default values for the Polling parameters are dependent on the value assigned to
the Modulation / Baud Rate parameter in the Radio tab.
Table 5.3 Polling Parameters
Sync Delay
Warning: This parameter should not be changed from its factory setting
without a clear understanding of radio protocol timing.
The “Sync Delay” parameter specifies the delay between the base station
transmission and the first response window, measured in milliseconds. The value
assigned to this parameter must be compatible with other hand-helds and base
stations in the system. The allowable range for this parameter is between 1 and 40.
Modulation / Baud Rate Sync Delay Window Delay Poll Timeout
4 Level / 19200 17 20 20
4 Level / 9600 17 23 25
2 Level / 9600 17 19 22
2 Level / 4800 25 23 37