Psion Teklogix 7530 G2 Hand-Held Computer User Manual 173
Chapter 5: Configuration
Decoded (Intermec ISCP)
5.11.4 Decoded (Intermec ISCP)
• Tap on the Scanner dropdown menu, and choose Decoded (Intermec ISCP).
5.11.4.1 Decoded (Intermec) Options
Laser On Time
The value assigned to this parameter determines how long the imager will remain on
when the scan button or trigger is pressed.
Double-tapping on this parameter displays a dialog box in which you can enter a
value between 1 and 10 seconds.
5.11.4.2 Decoded (Intermec) Advanced Options
Continuous Scan Mode
Setting this parameter to on keeps the imager on and continuously decoding as long
as the scanner button is pressed and held down.
Minimum Cancel Time
The value assigned to this parameter determines the time delay before the scanner is
turned off, once the scanner trigger or button is released. This gives the scanner a
minimum amount of time to complete its current decode before the scan is cancelled
when the user quickly triggers on/off.