Psion Teklogix 7530 G2 Laptop User Manual


 
Psion Teklogix 7530 G2 Hand-Held Computer User Manual 153
Chapter 5: Configuration
Non-Decoded Scanners
Include Number Sys
If this parameter is enabled, the number system digit is included with the decoded
bar code data.
Include Check
When enabled, the check digit is included with the decoded bar code data.
Addendum
Important: Before “Addendum” can take effect, the “Short Code” parameter
(see page 146) must be enabled.
Refer to “Addendum” on page 150.
Prefix/Suffix
Refer to page 151 for details.
5.11.2.8 Codabar
Enabled
Set this parameter to on to enable “Codabar” or off to disable it.
Strip Start/Stop Chars
Codabar uses the characters A, B, C, and D as start and stop characters. Thus, the
first and last digits of a Codabar message must be A, B, C, or D, and the body of the
message should not contain these characters. Setting this parameter to ON strips the
start and stop characters from this bar code.
Field Size/Chars
Refer to the description beginning on page 148 for details.
5.11.2.9 Code 93
Enabled
Set this parameter to on to enable “Code 93”.
Field Size/Chars
Refer to the description beginning on page 148 for details.