Q-Logic 9000 Network Cables User Manual


 
3 – FVIC Configuration and Monitoring Features
Fibre Channel Configuration
3-12 D000003-006 Rev. A
Q
1. In the main status and navigation area, click on a FVIC.
2. From the FVIC menu, click on Configuration.
3. Click on FCP Device Discovery. The Fibre Channel Target Device
Configuration window is displayed:
Figure 3-22. Fibre Channel Target Device Configuration Window
Any devices listed in the Configured Devices table have been previously
discovered and configured. The devices must have a status of Up in order to be
utilized by an SRP Initiator. A device will have a status of Down if it is no longer
logically connected to the FVIC port listed in the Port column. For example, if
the FVIC previously discovered the device through Port 1, and the Fibre Channel
cable has been moved to Port 2, the device will be displayed as Down.
4. If the desired device and FVIC port does not appear in the Configured Devices
table, click Start. All newly discovered devices are displayed in the Discovered
Devices table.
NOTE:A device will appear for each FVIC port connected to the same fabric
(e.g., multiple FVIC ports are connected to the same Fibre Channel switch).
Figure 3-23. Discovered Devices Table