Troubleshooting_ 6
3. Open the scan unit.
When the scanner lid is open, the scan unit cannot be opened. Do
not force the scan unit open, it can cause damage to the machine.
Close the scanner lid before opening the scan unit.
4. Ope
n the fuser cover.
5. Ope
n the inner cover.
Do not touch the fuser inside the inner cover. It is hot and could
cause burns!
6. Pu
ll up the paper jam lever in the direction of the arrow to separate the
fuser rollers and carefully remove the jammed paper from the unit.
7. Press down the paper jam lever to reapply pressure to the rollers.
8. C
lose the inner cover.
Before closing the inner cover, the jam lever must be fastened first
(step7). Otherwise, paper jam can occur.
If you do not see the jammed paper or if there is any resistance when
you pull, stop and go to the next step.
9. Open the inner cover of reverse unit and carefully remove the jammed
paper out of the machine.
If there is any resistance removing the paper or difficulty picking up
jammed paper, stop pulling and turn the release knob to the direction as