SANRAD V-Switch Switch User Manual


 
Chapter 6: Volume Configuration 105
Disk 3 Disk 4
Simple 2
Disk 1
Simple 1
Simple 4
Simple 3
Disk 2
Simple 8
Disk 5
Simple 7
Simple 10
Disk 6
Simple 9
Disk 7 Disk 8
10062
Simple 5 Simple 6 Simple 11 Simple 12
JBOD 1 JBOD 2
Mirrored
Volume 2
Mirrored
Volume 3
Figure 51. Second Mirrored Volume of RAID 10
If you are working in
a V-Switch cluster,
this volume must be
configured on both
V-Switches.
Finally, in Figure 52, page 106, a striped volume, Stripe 2, is created using
the two mirrored volumes as children: Mirror 2 and Mirror 3. The striped
unit size is 100 blocks, meaning that in each read/write function, 100
blocks of data are read/written first into Mirror 2 then Mirror 3 and then
back to Mirror 2 until the end of the data chunk.
volume create stripe –vol Stripe2 –sus 100 –ch Mirror2 –
ch Mirror3