SANRAD V-Switch Switch User Manual


 
58 SANRAD V-Switch User Manual
SWITCH PARAMETER DEFINITION STATUS EXAMPLE
-if
INTERFACE STORAGE PORT
NUMBER
MANDATORY
pscsi3
-id
IDENTITY SCSI BUS
IDENTITY
OPTIONAL
DEFAULT: 7
12
Example
Storage port 3, pscsi3, is assigned SCSI bus ID 12.
pscsi set busid –if pscsi3 –id 12
Viewing the FC Port Information
Use the CLI command fc interface show to view all FC ports on the V-
Switch; their World Wide Port Names (WWPN) and administrative and
operative types.
fc interface show
Alias WWPN Connect
Mode
Oper
Type
Speed
fc1 20:00:00:20:38:11:34:78 Provate NlPort 1Gbs
fc2 20:00:00:20:38:00:10:64 Private nlPort 1Gbs
Configuring an FC Storage Port
The V-Switch default configuration for FC connections is 1 GB nl port in a
public loop. If you want to change the default configuration, each storage
port connected to an FC device can be reconfigured to change the
connection speed, port type and connection mode. Use the CLI command
fc set to change the FC storage port communication speed; the port type
or connection mode.
fc set
You need to define four parameters to reconfigure an FC port:
SWITCH PARAMETER DEFINITION STATUS EXAMPLE
-if
INTERFACE STORAGE PORT MANDATORY
fc2
-sp
SPEED FC
COMMUNICATION
SPEED
OPTIONAL
AUTO: 0
1 GB: 1
2 GB: 2
1
-pt
PORT TYPE TYPE OF FC PORT OPTIONAL
N OR NL
nl