SANRAD V-Switch Switch User Manual


 
Chapter 6: Volume Configuration 87
The V-Switch also recognizes all write-protected storage devices. Use the
CLI command storage details to view a device’s details, including if it
is write-protected.
storage details
You need to define one parameter to view a disk’s details:
SWITCH PARAMETER DEFINITION STATUS EXAMPLE
-s
STORAGE ALIAS OF STORAGE
TO VIEW
MANDATORY
Disk2JBOD5
Table 19: Storage Details
Alias: Disk2JBOD5
Entity Name: 2000002037a9551e
LUN(Logical Unit Number) 0000000000000000
Vendor Name: SEAGATE
Additional Info:
Transport type: Fiber Channel
Oper. Status: Enabled
Time since last Update: 8 days 3h:12m:16 sec 37
(1/60 Sec)
SCSI Version: 3
Revision Level: 0002ST336704FC
Product Id: ST336704FC
Serial Number: 3CD0FHA400002108XYGLXYGL
Number Of Blocks: 71687369
Block Size: 512
SubDisks: Entire
Write Cache Enabled: true
Write Protected false
Volume sim