SANRAD V-Switch Switch User Manual


 
52 SANRAD V-Switch User Manual
Changing Management Parameters
After logging in to the V-Switch, you can change the general management
parameters and Telnet communications port as well as add user login
profiles.
Changing General Management Parameters
You can change V-Switch management parameters (IP address and mask)
or UDP port number as well as include details of whom to contact in the
event of technical difficulties and which read/write communities to send
traps to. Use the CLI command device set to add or change
management parameters. This command will not appear in the CLI menu
until the V-Switch is initialized.
device set
You can define or change thirteen parameters using this command:
SWITCH PARAMETER DEFINITION STATUS EXAMPLE
-n
NAME USER-ASSIGNED
NAME FOR THE
V-
S
WITCH
OPTIONAL
VSwitch1
-ip
MANAGEMENT IP
ADDRESS
IP
ADDRESS OF
THE MANAGEMENT
PORT
OPTIONAL
212.199.43.47
-im
MANAGEMENT IP
MASK
IP M
ASK FOR THE
MANAGEMENT PORT
OPTIONAL
DEFAULT:
255.255.255.0
-p
UDP PORT PORT THROUGH
WHICH ALL
UDP
COMMUNICATIONS
WILL FLOW
NAMELY FOR SNMP
OPTIONAL
DEFAULT: 161
-if
INTERFACE ALIAS ALIAS OF PORT FOR
MANAGING V-
S
WITCH
OPTIONAL
DEFAULT: MGMT
(ETH1 OR
MGMT)
-d
DATE LOCAL DATE OPTIONAL
21/07/2002
-t
TIME LOCAL TIME OPTIONAL
13:30
-c
CONTACT CONTACT PERSON
IN THE EVENT OF A
SYSTEM
MALFUNCTION
OPTIONAL
AnnaLevin