SANRAD V-Switch Switch User Manual


 
54 SANRAD V-Switch User Manual
Parameter Value
Object ID 1.3.6.1.4.1 10059 1.1.2
Time Since Last Reset 12 days 17 hours 29 min 32 sec
Mgmt IP Address 212.199.43.47
Mgmt UDP Port 161
Date & Time [DD/MM/YY] 21/04/02 13:33
Telnet Port 23
Eth Up
FC Up
Read Community Public
Write Community Private
Changing the Telnet Communications Port
If your Telnet communications connection to the V-Switch traverses a
firewall, the standard Telnet communications port 23 may be blocked by the
firewall as a security measure. To enable Telnet communications to the V-
Switch, you can designate an alternate port using the CLI command
device set -telnet. This port can be opened in the firewall for
dedicated Telnet-V-Switch communications.
device set -telnet
Example:
The port 1597 is programmed as the Telnet communications port.
device set -telnet 1597
Use the CLI command info to check the V-Switch’s designated Telnet port.
Adding an SNMP Manager
You can add a manager to the V-Switch. If you are working with
StoragePro, the V-Switch GUI management system, StoragePro will
automatically be included as a manager. If you are still not working with
StoragePro, there are no default managers defined for the V-Switch. You
can use the CLI command snmp manager add to add managers to the V-
Switch.
snmp manager add
SWITCH PARAMETER DEFINITION STATUS EXAMPLE
-ip
IP ADDRESS MANAGER IP
ADDRESS
MANDATORY
212.199.43.96
-p
UPD PORT PORT TO RECEIVE
TRAPS THROUGH
OPTIONAL
DEFAULT: 162
162