Schneider Electric 61 Network Router User Manual


 
Log parameters
110
Format of "Date" and "Time" parameters
Date and time are binary-coded using the corresponding word bits indicated in the table below.
Note: The value 0 for year corresponds to the year 2000 (2006 = 36, for example).
Bits 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Date
Year X X X X X X X
Month X X X X
Day X X X X X
Time
Hours X X X X X X X X
Minutes X X X X X X X X