Chapter 4 Maintaining the Sun Fire V40z Server
4-9
Verifying the Stepping Version In a Local Server
To verify the stepping version of your CPU(s) in a local server (with KVM attached):
1. Power on or reboot your server.
A message similar to the following example appears on the screen, and the memory
test begins.
This sample shows the output for a Sun Fire V40z server.
-----------------
PhoenixBIOS 4.0 Release 6.0
Copyright 1985-2002 Phoenix Technologies Ltd.
All Rights Reserved
Production RELEASE: System BIOS Revision = V2.18.9
SP Interface (PRS) Revision = 12
SP - BIOS Interface Active
xxxxxxxxxxxxxxxxxxxxxxxxxx
xx Sun Microsystems xx
xx Sun Fire V40z xx
xxxxxxxxxxxxxxxxxxxxxxxxxx
CPU = AMD Opteron(tm) Processor 850
4 Processors Detected, CG - CG - CG - CG
7743M System RAM Passed
1024K Cache SRAM Passed
ATAPI CD-ROM: CD-224E
Mouse initialized
-------------------------
2. During the memory test, hit the Pause key.
3. Verify the stepping version of the CPUs in the line similar to the following
examples:
2 Processors Detected, CG - CG
or
2 Processors Detected, E4 - E4