Sun Microsystems V20z Server User Manual


 
A-2
Sun Fire V20z and Sun Fire V40z Servers—User Guide March 2005
A.1.2 Sun Fire V20z Power Specifications
A.1.3 Sun Fire V20z Environmental Specifications
TABLE A-2
Sun Fire V20z Server AC Input Specifications
Specification Value
Universal AC Input 100 to 240 VAC, 50/60 Hz
Maximum current 7.0 amps
TABLE A-3
Sun Fire V20z Server Unit-Level Environmental Specifications
Specification State English Metric
Temperature Operating 50
°
to 95
°
F10
°
to 35
°
C
*
* The temperature specifications in this table are rated for sea level. For each rise of 300 meters in altitude, the
maximum temperature drops by 1° C.
Non-operating -40
°
to 149
°
F -40
°
to 65
°
C
Humidity Operating 10% to 90% RH at 80. 6
°
F
max. wet bulb (non-
condensing)
10% to 90% RH at 27
°
C
max. wet bulb (non-
condensing)
Non-operating 10% to 90% RH 10% to 90% RH
Altitude Operating Up to 9,800 feet Up to 3,000 meters
Non-operating Up to 39,370 feet Up to 12,000 meters
Vibration Operating .20 G, 5 to 500 Hz sine
sweep
Shock Operating 5 G, 11 ms half-sine