Chapter 3 Maintaining the Sun Fire V20z Server
3-11
9. In the SP SOL session that you launched in Step 1, you now see the output of the
BIOS CPU step screen.
For a sample of this output, see Step 1 in the previous procedure on page 3-9.
10. During the server’s memory self-test, terminate the remote session in order to
pause the screen:
a. Press Control-e.
b. Press the ‘c’ key.
c. Press the period key (.).
11. Verify the stepping version of the CPUs in the line similar to the following
examples:
2 Processors Detected, CG - CG
or
2 Processors Detected, E4 - E4
3.4.3 Support Guide for Half-Length PCI Card
Removed
In the original release of the Sun Fire V20z server, there is a plastic guide on the
motherboard for supporting a half-length PCI-X card. This support guide prevents
you from installing a full-length PCI-X card in the PCI 1 (66 MHz) position.
In the updated releases of the server, the guide has been removed. You can now
install a full-length PCI-X card in this slot.