Sun Microsystems V20z Server User Manual


 
3-26 Sun Fire V20z and Sun Fire V40z Servers—User Guide March 2005
FIGURE 3-21 Removing the Power Supply
5. Slide the power supply toward the front of the chassis and lift it out of the
chassis.
Installation is the reverse of this procedure.
6. Before re-installing the cover on the server, check the routing of all cables for
obstructions.
3.5.8 Cooling Fans
The following procedure describes how to replace a cooling fan.
1. Power off the server, including any attached peripherals, and disconnect the
server from the electrical outlet.
Refer to “Powering Off the Server and Removing the Cover” on page 3-2.
2. Identify the fan(s) to be replaced.
3. If you are replacing a processor cooling fan, unfasten the single screw securing
the center air baffle and lift the baffle away from the chassis (see
FIGURE 3-22).
Otherwise, continue with Step 4.