Symbol Technologies VC5090 Personal Computer User Manual


 
Application Development and Deployment 7 - 21
Readback checksum
error
-12 A checksum, generated from reading back data that was written to
the destination device, was incorrect. An error during transmission
or a write error to the destination device could cause this.
There is no more heap
space available
-14 There is no more heap space available for the download
procedure. Restart IPL and retry the download. If the failure
persists, contact service with details of what is being downloaded.
Insufficient data
available to complete
record
-21 A Symbol HEX file download was attempted but the HEX file is
invalid. Ensure the file is in Symbol HEX file format.
Invalid Symbol HEX file -23 A Symbol HEX file download was attempted but the HEX file is
invalid. Ensure the file is in Symbol HEX file format.
Unrecognized or
unsupported HEX record
-24 The Symbol HEX file being downloaded contains an invalid or
unrecognized HEX record. Ensure the file is in proper Symbol HEX
file format.
Invalid data in HEX file -25 The Symbol HEX file being downloaded contains invalid data.
Ensure the file is in proper Symbol HEX file format with valid HEX
data.
Exceeded max size -26 The download file is too large to fit into the space allocated for it.
Either make the file smaller or increase the space allocated for it by
altering the partition table.
Partition is not valid on
this device
-27 The downloaded file specifies a partition entry that does not exist
on the device. Only download files that are valid for this device, or
change the partition table so that the new file is valid on the device.
Wrong destination code -28 A specific partition was chosen from the Main Menu (not Auto
Select) but the file selected for download was for another partition.
Ensure that the partition selected from the Main Menu matches the
file selected for download.
File type does not
support IPL Auto Select
-29 Monitor, Power Micro and Partition Table cannot be loaded with
Auto Select. Select the appropriate area, and try again.
Non-contiguous record
found
-30 A Symbol HEX file download was attempted but the HEX file is
invalid. Ensure the file is in Symbol HEX file format.
Timed Out - No data -31 IPL was waiting for data from the source device but timed out
before receiving any. Check the source device connectivity and
retry.
Fail: Buffer Overrun -32 The serial port device could not keep up with incoming data. Retry
the serial download with a lower baud rate.
Table 7-4
IPL Errors
Error Text Error Number Probable Cause