Chapter 4 Provisioning the TimeProvider
Provisioning the Input Reference
108 TimeProvider User’s Guide 097-58001-02 Revision G – April 2008
Provisioning the Input Reference
You need to know the following information about the input reference signal before
you can provision the Input Reference signals:
Input selection mode
Interface type
Frame type/frequency
Quality level
Priority level
SSMs and bit position
CRC
Setting the Input State
Use the ED-EQPT command to provision the inputs to the TimeProvider. You can
enable, disable, or place an input in Monitor mode (where the input is monitored, but
cannot be selected as the system reference).
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
Sample Command
ED-EQPT::INP1:TS1000::INSTATE=MONITOR;
This command places Input 1 in the Monitor mode.
Autonomous Message
TP-SSU 03-10-24 10:44:21
A 1178 REPT EVT
“INP1,T1:NA,INSTATE,NSA,03-10-24 10-44-21:\"INPUT STATE
HAS CHANGED,MONITOR\””
;
<aid> <keyword> <value> Description Default value
PRS
INPp (p = 1 | 2)
GPS
INSTATE ENABLE Enables the specified input ENABLE
GPS = DISABLE
MONITOR Places the specified input in
Monitor Only mode
DISABLE Disables the specified input