Symmetricom 1100 Clock User Manual


 
Chapter 4 Provisioning the TimeProvider
Provisioning NTP Parameters
122 TimeProvider User’s Guide 097-58001-02 Revision G – April 2008
Provisioning Cut-thru Mode
Use the ED-SYNC command to set the cut-thru mode for each port (1 or 2) on the
Retimer module. You can enable cut-thru mode when the local oscillator (LO) enters
either the free-run or holdover mode.
ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
Sample Command
ED-EQPT::RTMA-1:TS1000::FREEFLT=CUTTHRU;
This command sets the Retimer to enter cut-thru mode when the local oscillator
enters free-run mode.
Autonomous Message
TP-SSU 03-10-24 11-09-12
A 1189 REPT EVT
“RTMA,EQPT:NA,OUTSTATE,NSA,03-10-24 11-09-12:\"CUTTHRU
STATE HAS CHANGED,CUTTHRU\””
;
Provisioning NTP Parameters
This section describes how to enable and provision the Network Time Protocol
(NTP) feature in the TimeProvider. There are TL1 commands that allow you to:
Activate the NTP feature
Edit the NTP parameters
<aid> <keyword> <value> Description Default value
RTMg[-p]
g = A | B | C | D
p= 1 | 2
FREEFLT CUTTHRU Cut-thru mode is engaged
when the LO enters
free-run mode.
RETIME
RETIME Cut-thru mode is not
engaged when the LO
enters free-run mode.
HOLDFLT CUTTHRU Cut-thru mode is engaged
when the LO enters
holdover mode.
RETIME
RETIME Cut-thru mode is not
engaged when the LO
enters holdover mode.