Table 6-8 describes the conditions that generate the associated event.
Table 6-8. Conditions Causing an Event
Event ID Condition
ACCLVL User Access Level has changed
ACO Audio alarm is deactivated
IMC Codes
ALMCHG Alarm parameter has changed <keyword>,<alarm>
AOMERGE Autonomous event reporting has changed <state>
BAUD Serial port baud rate has changed <value>
CMDCHG Command access level has changed <command>
ECHO Serial port echo mode has changed <state>
FLOW Serial port flow control has changed <state>
FWFAIL Firmware upgrade unsuccessful
FWOK Firmware upgrade successful
IMCBIST User has requested the IMC to perform a Built-in Self Test
INACTTIME Communications timeout has changed <value>
INITLOG Event log has been cleared
IPADDR IP address has changed <value>
IPGATE Gateway IP address has changed <value>
IPHOST1 The IMC Ethernet address for element host manager has changed <value>
IPHOST2 The IMC Ethernet address for element host manager has changed <value>
IPHOST3 The IMC Ethernet address for element host manager has changed <value>
IPHOST4 The IMC Ethernet address for element host manager has changed <value>
IPSUB Subnet mask IP address has changed <value>
ISDIFF Configuration images are different
ISEQ Configuration images are the same
LOGECHO Login event has changed <state>
LOGIN User logged in <username>
LOGOUT User logged out <username>
PIDCHG User password has changed
RESET Module has been reset