Symmetricom 1100 Clock User Manual


 
097-58001-02 Revision G – April 2008 TimeProvider User’s Guide 129
Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
<aid> = INP1 or INP2
INPDISQ Specified input has
been disqualified or
qualified as a possible
system reference.
MN | MJ |
CR
FLT
DELAY
Yes MN MN
INPAIS The specified input is
receiving an Alarm
Indication Signal.
1
MN | MJ |
CR
IMMED No MN MN
INPLOS The specified input has
Loss of Signal.
1
MN | MJ |
CR
IMMED No MN MN
INPOOF The specified input is
receiving an Out of
Frame signal.
1
MN | MJ |
CR
IMMED No MN MN
INPFRQ Specified input port’s
calculated received
frequency exceeds the
pull-in range of the
LO.This alarm condition
disqualifies the input as
a possible reference.
2
NR | NA |
MN | MJ |
CR
IMMED No MN NR
INPPHASE Specified input port’s
phase measurement
exceeds usable value.
NR | NA |
MN | MJ |
CR
IMMED No MN MN
INPQL
The received SSM is of
lesser quality than the
provisioned QLEVEL for
a specified input. This
alarm occurs when you
provision the input’s
QLEVEL below the
quality level of the LO.
NR | NA |
MN | MJ |
CR
IMMED No MN MN
EXDSC
Input has had excessive
discontinuities, indicated
by more than 3 signal
faults (OOF, BPV, CRC,
or AIS) within a 5-minute
window. The alarm
clears when the 5-
minute window contains
less than 3 signal faults.
NR | NA |
MN | MJ |
CR
IMMED No MN MN
Table 4-3. Alarm Conditions and Defaults (Continued)
Alarm ID
Description of Alarm
Condition
Possible
Alarm
Levels
Error
Delay
Default
Error
Delay
Editable?
Default Level
SSU
Mode
SUB
Mode