Symmetricom 1100 Clock User Manual


 
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
178 TimeProvider User’s Guide 097-58001-02 Revision G – April 2008
CLK
BRDG
Local oscillator in the specified
IOC is in Bridging mode.
EQPTNSANANAMJ
CLK
HOLD
Local oscillator in the specified
IOC is in Holdover mode.
EQPT SA MJ MJ MJ
CLK
FREE
Local oscillator in the specified
IOC is in the Free-run mode.
EQPT SA MJ MJ MJ
CLK
WARM
Local oscillator in the specified
IOC is in the Warm-up mode.
EQPT SA MN MN MN
SYNTH
EOR
Synthesizer generating the
output frequency has reached a
defined End-of-Range for the
oscillator.
EQPT SA MJ MJ MJ
AID = IOC2
IOC2
COMM
Communication alarm with IMC
and IOC2.
EQPTNSAMNMNMN
IOC2TO
1 COMM
Communication alarm from
IOC2 to IOC1.
EQPTNSAMNMNMN
IOCFAIL Summary alarm for IOC
hardware failures not specified
in other alarms.
EQPT SA MJ MJ MJ
BTBCK
UP
All BesTime backup sources
are unusable to the BesTime
engine.
EQPTNSANANANA
CLK
BRDG
Local oscillator in the specified
IOC is in Bridging mode.
EQPTNSANANAMJ
CLK
HOLD
Local oscillator in the specified
IOC is in Holdover mode.
EQPT SA MJ MJ MJ
CLK
FREE
Local oscillator in the specified
IOC is in the Free-run mode.
EQPT SA MJ MJ MJ
CLK
WARM
Local oscillator in the specified
IOC is in the Warm-up mode.
EQPT SA MN MN MN
SYNTH
EOR
Synthesizer generating the
output frequency has reached a
defined End- of-Range for the
oscillator.
EQPT SA MJ MJ MJ
AID = GPS
Table 6-7. Alarm Codes (Continued)
Event ID Description
AID
TYPE
Service
Affecting
Alarm Level
SSU
Mode
PRR
Mode
SUB
Mode