Symmetricom 1100 Clock User Manual


 
097-58001-02 Revision G – April 2008 TimeProvider User’s Guide 119
Chapter 4 Provisioning the TimeProvider
Provisioning the Outputs
Enabling and Disabling the Outputs
Use the ED-EQPT command to enable or disable the output signal. This command
affects the specified group of eight output channels, or sixteen output channels if the
Expansion panel is also used; individual channels cannot be enabled or disabled.
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
Sample Command
ED-EQPT::OUTA:TS1000::OUTSTATE=DISABLE;
This command disables output group A and turns off all 8 channels, or 16 channels
if the Expansion Panel is also used.
Autonomous Message
TP-SSU 03-10-24 11-09-12
A 1189 REPT EVT
“OUTA,EQPT:NA,OUTSTATE,NSA,03-10-24 11-09-12:\"OUTPUT
GROUP STATE HAS CHANGED,DISABLE\””
;
Provisioning the Output Framing Type
Use the ED-SYNC command to provision the output framing type.
CAS and CCS are available for E1 output framing. D4 and ESF are available for T1
output framing.
ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
<aid> <keyword> <value> Description Default value
OUTg
g = A | B | C | D
OUTSTATE ENABLE Enable the specified
output group
ENABLE
DISABLE Disable the specified
output group
<aid> <keyword> <value> Description Default value
OUTg
g = A | B | C | D
FRMTYPE 8K | 1.544M | 2M |
6.312M | CAS | CCS |
D4 | ESF | CC | JCC |
JCC4 | ISOLATED_1 |
Provisions the output
framing
2M