Chapter 7 Specifications of the TimeProvider
Communications Ports
194 TimeProvider User’s Guide 097-58001-02 Revision G – April 2008
Communications Ports
Serial Ports
Two EIA-232 serial ports are available: the local Craft port and the Remote port.
Specifications are listed in Table 7-1.
Table 7-1. Serial Port Specifications
Specification Factory Default Available
Local Craft Port
Baud rate 9600 2400, 9600, 19200, 28800,
34800, 57600, 115200
Word length 8 bits 8 bits
Parity None None, Odd, Even
Stop bits 1 1
Echo Off Off, On
Software flow control
XON/XOFF
Off Off, On
Hardware flow
control CTS/RTS
Off Off, On
RS-232 configuration DCE DCE
Remote Port
Baud rate 9600 2400, 9600, 19200, 28800,
34800, 57600, 115200
Word length 8 bits 8 bits
Parity None None, Odd, Even
Stop bits 1 1
Echo Off Off, On
Software flow control
XON/XOFF
Off Off, On
Hardware flow
control CTS/RTS
Off Off, On
Handshake
DTR/DSR
On On
RS-232 configuration DTE DTE