Toshiba F30 Personal Computer User Manual


 
3 Tests and Diagnostics 3.31 Bluetooth Test program
3-90 [CONFIDENTIAL] QOSMIO F30 Maintenance Manual (960-555)
Table 3-8 Common Error code
Error code Meaning
0x30
BT Control Status is not Disable.
0x31
BT Control Status is not Enable.
0x32
Power Status is not OFF.
0x33
Power Status is not ON.
0x34
USB I/F Status is not Attach.
0x35
USB I/F Status is not Detach.
0x36
Wake-up Status is assert
0x37
Wake-up Status is not assert.
0x38
Switch Status is ON.
0x39
Switch Status is OFF.
0x3a Module does no exist.
0x3b Module exists.
0x3c Incorrect command line
0x3d Sideband access driver does not exist always.
0x3e
DOS Bluetooth driver for DOS does not exist always.
0x3f Get Status for Sideband access drive functions abnormally.
0x40 No response to Inquiry
0x41 Device Descriptor can not inquire abnormal USB I/F
0x42 Sideband Reset time our
0x43 Incorrect Descriptor type
0x44 Descriptor has been got despite of Detach condition
0x45 Abnormal setting file open
0x46 Incorrect contents of setting file
0x47 Incorrect BD_ADDR (00)
0x48 Incorrect BD_ADDR (FF)
0x49 Incorrect BD_ADDR (bit0=1)
0x4a Incorrect BD_ADDR (bit1=1)
0x4b Incorrect BD_ADDR (address defined as an error)
0x4c Confirmation of hardware switch interrupted.
0x4d RSSI is lower than specified value
0x4e Interrupted
0x4f (reserved)
The codes of 0x30 to 0x4f are common error code in the test program (IMCSXXXX)