Toshiba W7 Computer Drive User Manual


 
W7 ASD Installation and Operation Manual 115
RX2 Torque Reference Setpoint #1
Program Frequency Settings Speed Reference Setpoints RX2
RX2 Torque Reference Setpoint #1
This parameter is used to set the direction, gain, and bias of the RX2 input
terminal when the RX2 terminal is used as the control input while operating in
the Torque Control mode.
RX2 Input Torque Control Setup
Perform the following setup to allow the system to receive Torq ue control input
at the RX2 input terminal:
Program Utilities Command and Frequency Settings Command
Mode Select
Terminal Block.
Program Utilities Command and Frequency Settings Frequency#1
Mode Select
RX2.
Provide a Run command (F and/or R).
Torque Control
Perform the following setup to allow the system to perform Torque control
from the RX2 input terminal:
•Set RX2 Torque Reference #1,
•Set the RX2 input signal level (RX2 Speed Ref #1) that represents the RX2
Torque Reference #1,
•Set RX2 Torque Reference Setpoint #2, and
•Set the RX2 input signal level (RX2 Speed Ref #2) that represents the RX2
Torque Reference Setpoint #2.
This is accomplished by establishing an associated V/f output pattern for a
given RX2 input level.
This parameter sets RX2 Torque Reference #1 and is the output torque value
that is associated with the setting of
RX2 Speed Reference Setpoint #1 when
operating in the Torque control mode.
This value is entered as -250 to +250% of the rated torque.
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — -250.0
Maximum — +250.0
Units — %
Torque Settings
RX2 Torque Reference Setpoint #2
Program Frequency Settings Speed Reference Setpoints RX2
RX2 Torque Reference Setpoint #2
This parameter is used to set the direction, gain, and bias of the RX2 input
terminal when the RX2 terminal is used as the control input while operating in
the Torque Control mode.
This is accomplished by establishing an associated V/f output pattern for a
given RX2 input level.
See RX2 Torque Reference Setpoint #1 for further information on this setting.
This parameter sets RX2 Torque Reference #2 and is the output torque value
that is associated with setting of
RX2 Speed Reference Setpoint #2 when
operating in the Torque control mode.
This value is entered as -250 to +250% of the rated torque.
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — -250.0
Maximum — +250.0
Units — %
RX2 Torque Reference Setpoint #1 RX2 Torque Reference Setpoint #2