Xantrex Technology XTR 850 Watt Power Supply User Manual


 
Analog Programming Mode
975-0200-01-01 4-15
4
Resistive-Controlled Voltage APG Setup
To activate APG voltage mode using an external resistor:
1. Turn the mode control knob to the VAP position or press the Rotary
knob/Enter button if the control knob is already at the VAP position.
UAPr is displayed on the output voltage display.
2. Turn the Rotary knob/Enter button to select Rn1S (resistor source from
non-isolated connector).
3. Press the Rotary knob/Enter button to commit the selected mode.
LE U is displayed on the output voltage display.
4. Select the input source level using the Rotary knob/Enter button.
5. Once the desired level has been selected, press the Rotary knob/Enter
button to commit the change.
The display will return to the normal display.
Deactivating APG Voltage Mode
To deactivate the APG voltage mode:
1. Turn the mode control knob to the VAP position or press the Rotary
knob/Enter button if the control knob is already at the VAP position.
2. UAPr is displayed on the output voltage display.
3. Turn the Rotary knob/Enter button to select nonE.
4. Press the Rotary knob/Enter button to commit the change.
The display will return to the normal display.
Query for Analog Voltage Input Level
To query for analog voltage input level from non-isolated input:
1. Turn the mode control knob to the VAP position or press the Rotary
knob/Enter button if the control knob is already at the VAP position.
UAPr is displayed on the output voltage display.
2. If the mode is currently nonE then select any other APG mode. If this
step is done, be sure to restore the APG setting to nonE when the
operation is complete. Otherwise, do not rotate the Rotary knob/Enter
button to keep the current APG mode.
3. Press the Rotary knob/Enter button to select the APG mode.