A-24 975-0200-01-01
SCPI Command Reference
Select Current
Analog
Programming
Input Voltage
Input Level/
Range
[:]SYSTem[<channel>]:COMMunicate
:APRogram:LEVel:CURRent[:ISOLated]
Select level for Current
APG. Level can be between
2 -10 volts.
?|<Level(2–
10)>|MAXimum|MI
Nimum
Yes
Select the
address to
communicate
with.
[:]SYSTem[<channel>]:COMMunicate
[:MCHannel]:ADDRess
Select the current device to
receive the commands. The
parameter for this
command is the address set
on the front panel under the
remote
Yes
Select
Address
[:]SYSTem:COMMunicate[:SELF]:ADDRess
Select the power supply
unit to communicate with.
?|<Address (1–30) Yes
Setup the
Voltage
control source
for Isolated
APG.
[:]SYSTem[<channel>]:REMote:SOURce
[:VOLTAGage]:ISOLated
Alter or query the state of
the remote programming
Isolated Voltage APG
source.
?|LOCal|AVOLtage
|ARESistive
Yes
Setup the
Voltage
control source
for Non-
Isolated APG.
[:]SYSTem[<channel>]:REMote:SOURce
[:VOLTAGage]:[NISOlated]
Query remote control
source for voltage.
?|LOCal|AVOLtage
|ARESistive
Yes
Setup the
Current
control source
for Isolated
APG.
[:]SYSTem[<channel>]:REMote:SOURce
:CURRent:ISOLated
Query remote control
source for isolated voltage.
?|LOCal|AVOLtage
|ARESistive
Yes
Table A-9
System Commands (Continued)