Step 3: Connecting AC Input Power
975-0200-01-01 2-5
2
Step 3: Connecting AC Input Power
XTR 850 Watt AC Input Connector
On the XTR 850 Watt, the AC input connector is a standard IEC 16 A
250 V male connector located on the rear panel of the power supply. The
AC input cord provided is rated for 30
A, 300 V and appropriate for use
in any country.
WARNING: Shock hazard
Disconnect AC power from the unit before removing the cover. Even with the
front panel power switch in the Off position, live line voltages are exposed when
the cover is removed. Repairs must be made by an Authorized Service Center.
WARNING
There is a potential shock hazard if the power supply chassis and cover are not
connected to an electrical ground via the safety ground in the AC input
connector. Ensure that the power supply is connected to a grounded AC outlet
with the recommended AC input cord configured for the available line voltage as
described in this section.
WARNING
The AC input cord is the disconnect device for the power supply. The plug must
be a non-locking plug which is readily identifiable by and accessible to the
operator. The input cord must be no longer than 9.84 feet (3 m).