Xantrex Technology XTR 850 Watt Power Supply User Manual


 
C-6 975-0200-01-01
Specifications
Remote Operation
Table C-3
Remote Operation
Programming Mode APG ISOL Digital
Voltage and Current Output Voltage Programming 0–100%, 2~ up to 10 V, programmable
Current Output Resistor Programming 0–100%, 2~ up to 10 kΩ, programmable
Voltage Output Resistor Programming 0–100%, 2~ up to 10 kΩ, programmable
Output Voltage and Current Monitor 0–100%, 2~ up to 10 V, programmable
Voltage Programming Accuracy (mV) ± 0.5% of rated output voltage ±0.1% of rated output voltage
Current Programming Accuracy (mA) ± 1% of rated output current ±0.2% of rated output current
Voltage Readback Accuracy (mV) ± 1% of rated output voltage ±0.1% of rated output voltage
Current Readback Accuracy (mA) ± 1% of rated output current ±0.2% of rated output current
Isolation (Prog and Readback Lines) With respect to chassis potential:
500
V
With respect to:
chassis potential: 500 V.
negative or positive main output: 1500 V.
negative or positive auxiliary output:
300
V.
Voltage and Current Programming Resolution 0.012% of full scale
Voltage and Current Readback Resolution
Parallel Operation Up to 4 units in master/slave
mode
Series Operation Up to 2 units (with external
diodes)
Constant Voltage (CV)/Constant Current (CC) Indicator CV: TTL High (4–5 V)
CC: TTL Low (0–0.6 V)