Xantrex Technology XTR 850 Watt Power Supply User Manual


 
Contents
xi 975-0200-01-01
Current Configuration Memory Settings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–27
User Setting Memory Locations - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–28
Saving User Setting Memory Locations - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–28
Recalling User Setting Memory Locations - - - - - - - - - - - - - - - - - - - - - - - - - 3–29
Local Lockout - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–30
Enabling Local Lockout - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–30
Disabling Local Lockout - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–30
Using the External Shutdown Function - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–31
Activating the External Shutdown Function - - - - - - - - - - - - - - - - - - - - - - - - 3–31
Controlling the External Shutdown Function - - - - - - - - - - - - - - - - - - - - - - - - 3–31
Defining the Polarity of the External Shutdown Signal - - - - - - - - - - - - - - - - - 3–31
Interlock Function - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–33
Defining the Interlock Mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–33
Power On Status Signal - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–33
Hardware Malfunction Alarms- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–34
Resetting the Power Supply - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–35
Using Multiple Power Supplies - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–37
Configuring Multiple Supplies for Series Operation - - - - - - - - - - - - - - - - - - - 3–39
Configuring Multiple Supplies for Current Sharing Operation (APG Method) - 3–41
Connecting to the Load in Local Sensing Mode (Parallel Control Method) - - - 3–43
Connecting to the Load in Remote Sensing Mode (Parallel Control Method) - - 3–44
4
Analog Programming (APG) and Isolated Analog Programming
(ISOL)
Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -4–2
Analog Programming (APG) of Output Voltage and Output Current - - - - - - - - -4–2
Remote Programming Options - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -4–3
Analog Programming (APG) Connector J1 - - - - - - - - - - - - - - - - - - - - - - - - - -4–5
Analog Programming Mode- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -4–9
Analog Programming With External Voltage Source - - - - - - - - - - - - - - - - - - -4–9
Voltage-Controlled Voltage APG Setup - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–10
Voltage-Controlled Current APG Setup - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–12
Resistive-Controlled Voltage APG Setup - - - - - - - - - - - - - - - - - - - - - - - - - - 4–15
Resistive-Controlled Current APG Setup - - - - - - - - - - - - - - - - - - - - - - - - - - 4–17
Voltage and Current Readback - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–18
Isolated Analog Programming Mode (ISOL) - - - - - - - - - - - - - - - - - - - - - - - - - - 4–19
AUX Output and Isolated Analog Programming (ISOL) Connector - - - - - - - - 4–19