OPERation Status Register
975-0200-01-01 5-35
5
Current SHare Sub-Register
This register shows the state of the current share configuration, which can
either be set through the front panel Current Share Config menu, or
through the SCPI command.
The SCPI command (s) for these instructions are:
[[:]SOURce]:COMBine:CSHare[:MODE]
Table 5-12
OPERation SHUTdown Status Register
Bit Bit Weight Bit Name Description
0 1 PROTection Reflects the summary of the PROTection sub-
register.
1 2 INTerlock The power supply is shut down by INTerlock signal.
2 4 Not Used Not Used
3 8 External Shutdown The power supply is shut down by External
Shutdown signal.
Table 5-13
OPERation SHUTdown PROTection Status Register
Bit Bit Weight Bit Name Description
0 1 OVP Over Voltage protection has tripped.
1 2 UVP Under Voltage protection has tripped.
2 4 Not Used Not Used
3 8 Not Used Not Used
4 16 AC Off AC failure protection has tripped.
5 32 OTP Over Temperature protection has tripped.
6 64 Not Used Not Used
7 128 Foldback Foldback protection has tripped.
8 256 Fan Fan failure protection has tripped.