Xantrex Technology XTR 850 Watt Power Supply User Manual


 
A-26 975-0200-01-01
SCPI Command Reference
Alarm
Masking
[:]SYSTem[<channel>]:PROTection[:MASK]
Enable/disable alarms/
protection.
?|<Alarm Mask - (0–
255)
Yes
Set Alarm
Output
Latches
[:]SYSTem:PROTection:LATCh
Sets the Alarm Output
Latches. See
Table 3-6 on
page 3–21.
?| <Sum of output
latch flags>
Yes
Table A-10
Status Commands
Function SCPI Command Description
Parameter and
Range
Query
Query
Operation
Status
Condition
Register
[:]STATus[<channel>]:OPERation
:CONDition?
Query the Operations
Condition Register.
See Table 5-11 on page 5–
34.
Yes
Set Operation
Status Enable
Register
[:]STATus[<channel>]:OPERation:ENABle
Access the Operations
Enable Register.
See Table 5-11 on page 5–
34.
?|<Enable Flags -
(0–65535)>
Yes
Query
Operation
Status Event
Register
[:]STATus[<channel>]:OPERation[:EVENt]
?
Query the Operations Event
Register.
See Table 5-11 on page 5–
34.
Yes
Set Operation
Status
Negative
Transition
Register
[:]STATus[<channel>]:OPERation
:NTRansition
Access the Operation
Negative Trans Filter
Register.
See Table 5-11 on page 5–
34.
?|<Transition Flags
- (0–65535)>
Yes
Table A-9
System Commands (Continued)