Xerox 4890 IPS Printer User Manual


 
PRINTER SPECIFICATIONS AND REQUIREMENTS
6-2 XEROX DOCUPRINT 4850/4890 IPS INSTALLATION PLANNING GUIDE
Outlet configurations
This section discusses specifications for the DocuPrint system
outlets and the required wall outlet configurations for the USA /
Canada and internationally.
Note: All power outlets must be dedicated to this equipment. When
determining the electrical connections for your system, make sure
that:
Each power cord has a separate circuit
The printer power cord configurations match your receptacle
Your electrical outlets are within the required specifications.
50 Hz systems: Ensure that power connections are per local codes/
regulations.
Printer outlet voltages60 Hz
The following table shows the voltages for the outlets on your printing
system. All power outlets must have a dedicated circuit for each
system equipment piece.
Printer power cord configurations The following figure shows the 60 Hz power cord configuration for
30 amp NEMA 14-30R. Voltage to ground is shown for
troubleshooting purposes.
Figure 6-1. 60 Hz power configuration
Table 6-5. 60 Hz voltage requirements at power outlet
Measurement of wiring Nominal Range
Line 1 to neutral 120 V 105 to 127 V
Line 2 to neutral 120 V 105 to 127 V
Neutral to ground 0 V 0 to 10 V
Line 1 to line 2 208 V 181 to 220 V
Line 1 to ground 120 V 105 to 127 V
Line 2 to ground 120V 105 to 127 V
Neutral
Line 1
Ground
Line 2
105 to 127 VAC
105 to
127 VAC
105 to 127 VAC
105 to 127 VAC
0 to 10 VAC
181 to 220 VAC
NEMA
14-30R