Xerox 4890 IPS Printer User Manual


 
PRINTER SPECIFICATIONS AND REQUIREMENTS
6-4 XEROX DOCUPRINT 4850/4890 IPS INSTALLATION PLANNING GUIDE
Environmental specifications
When you select a site location for your DocuPrint printer, avoid
environments with extreme variations in temperature and other
hazards, such as excessive dust or humidity. Recommended
environmental ranges for the work area are as follows:
Table 6-8. Environmental specifications for 4850/4890
Condition Range
Temperature: Recommended:
Minimum:
Maximum:
72° F ± 4° F
22° C ± 2° C
60° F / 15.5 °C
80° F / 26.7° C
Humidity: Recommended:
Minimum:
Maximum:
45% ±10%
30%
65%
Altitude: Normal:
Maximum:
Up to 6,000 feet / 1,830 m
above sea level
9,000 feet / 2,743 m above
sea level.
4850 Printer - 60 Hz heat dissipation Operating:
Standby:
11,200 BTU/hour
7,400 BTU/hour
4850 Printer - 50 Hz DELTA heat dissipation: Operating:
Standby:
11,200 BTU/hour
7,400 BTU/hour
4890 Printer - 60 Hz heat dissipation: Operating:
Standby:
14,980 BTU/hour
9,100 BTU/hour
4890 Printer - 50 Hz DELTA heat dissipation: Operating:
Standby:
14,980 BTU/hour
9,100 BTU/hour