Chapter 27 User/Group
ZyWALL 110/310/1100 Series User’s Guide
381
The following table describes the labels in this screen.
27.4.2 User Aware Login Example
Access users cannot use the Web Configurator to browse the configuration of the ZyWALL. Instead,
after access users log into the ZyWALL, the following screen appears.
Figure 248 Web Configurator for Non-Admin Users
Table 138 Configuration > Object > User/Group > Setting > Edit
LABEL DESCRIPTION
User Type This read-only field identifies the type of user account for which you are configuring the
default settings.
admin - this user can look at and change the configuration of the ZyWALL
limited-admin - this user can look at the configuration of the ZyWALL but not to
change it.
user - this user has access to the ZyWALL’s services but cannot look at the
configuration.
guest - this user has access to the ZyWALL’s services but cannot look at the
configuration.
ext-user - this user account is maintained in a remote server, such as RADIUS or
LDAP. See Ext-User Accounts on page 372 for more information about this type.
ext-group-user - this user account is maintained in a remote server, such as
RADIUS or LDAP. See Ext-Group-User Accounts on page 372 for more information
about this type.
Lease Time Enter the number of minutes this type of user account has to renew the current session
before the user is logged out. You can specify 1 to 1440 minutes. You can enter 0 to
make the number of minutes unlimited.
Admin users renew the session every time the main screen refreshes in the Web
Configurator. Access users can renew the session by clicking the Renew button on their
screen. If you allow access users to renew time automatically (see Section 27.4 on page
378), the users can select this check box on their screen as well. In this case, the
session is automatically renewed before the lease time expires.
Reauthentication
Time
Type the number of minutes this type of user account can be logged into the ZyWALL in
one session before the user has to log in again. You can specify 1 to 1440 minutes. You
can enter 0 to make the number of minutes unlimited. Unlike Lease Time, the user has
no opportunity to renew the session without logging out.
OK Click OK to save your changes back to the ZyWALL.
Cancel Click Cancel to exit this screen without saving your changes.