B-9
ACU for DOS
Notes:
■
InitializeAll
is a global keyword that you need to
specify only once.
■
InitializeAll
is always performed prior to array
creation regardless of its position in the script.
■ If both
InitializeAll=Yes
and
InitializeAll=No
are
specified in the same script file,
InitializeAll=Yes
is
always the overriding value.
■ If an array is deleted during a build/verify process, the
process is automatically terminated.
Possible values are as follows:
■ Yes—Initialize all drives.
■ No (the default)—Do not initialize all drives; only those drives
specified with the
Drives
keyword are initialized.
Examples
Type=Volume
Type=RAID1
Method Keyword
Method
is an optional keyword, indicating which method to use
when creating a redundant (RAID 1, 5, and 10) array. Possible
values are:
■
Build
(the
default
)—Perform a build/verify process on the array.
Takes longer than
Clear
, but allows you to begin using the array
immediately.
■ Clear—Clear the array. Faster than a build/verify process, but
you have to wait for the operation to be completed before you
can begin using the array.
■
Quick Init
—Makes the array available immediately, but does not
accomplish a build/verify. Parity and mirror information is created
as data is written to the drive (called full-stripe write mode), which
reduces overall array performance. Maximum performance is
achieved by starting and completing a build/verify.
Example
Method=Build