ADC Campus-REX2 RS Network Card User Manual


 
Chapter 6 - Managing Software
92 Campus-REX2 RS Interface Card User Manual
UPGRADING CAMPUS UNIT SOFTWARE
This section describes how to upgrade the software on your Campus-REX2.
To upgrade, you will use FTP on your Windows- or Unix/Linux-based PC to
transfer the new software to the Campus-REX2. A file containing the new
software is supplied with the name carex2_Vx.y.tar, where x.y is the software
release version. When you upgrade software, the configured parameters for
HDSL, system, and REX2 are not affect by the upgrade.
Prior to updating software, ensure the following has been completed:
The Campus-REX2 is configured with a LAN IP address (see
“Configuring the REX2” on page 29.)
You can successfully 'ping' the configured LAN IP address of the
Campus-REX2.
You have access to the file containing the upgrade software
(carex2_Vx.y.tar) from the PC that you used to perform the 'ping'.
Do not remove power to the Campus unit or disconnect the
Line and LAN side network connections when upgrading
software or saving configuration.