ADC Campus-REX2 RS Network Card User Manual


 
Chapter 5 - Monitoring and Testing the Campus System
76 Campus-REX2 RS Interface Card User Manual
The information on the Current System Status menu does not update
automatically. To update this information, type then press .
To clear the 24 Hour ES and 24 Hour UAS counters, type then press
.
Viewing 24-Hour Performance History
This screen displays historical HDSL information for the last 24 hours and is
presented in 15-minute increments.
From the System Status Menu, type then press . The 24 Hour
HDSL Performance History screen is displayed.
The 24 Hour HDSL Performance History screen provides the following
information:
HDSL-A represents a single pair or the first pair (or loop) of a two-pair
implementation (dependent on how HDSL was implemented for your
Campus system. HDSL-B represents the second pair (or loop) of a
two-pair implementation.
Local indicates the Campus unit into which you are logged for
management. Remote indicates the Campus unit at the other end of the
HDSL connection from the local unit.
ES/UAS indicates the total number of errored seconds and unavailable
seconds that occurred during this 15-minute time frame.
U ENTER
C
ENTER
2 ENTER
Jul 07, 2003 ADC TELECOMMUNICATIONS, CAMPUS RS, Version 5.1 08:19:34
Local Unit ID: Southall Quad 4 Local I/F: REX2
Remote Unit ID: Central Remote I/F: REX2
Circuit ID: Southeast line 421
24 HOUR HDSL PERFORMANCE HISTORY
HDSL-A HDSL-B
LOCAL REMOTE LOCAL REMOTE
ES/UAS ES/UAS ES/UAS ES/UAS
-------- -------- -------- --------
11:00 000/000 000/000 000/000 000/000
11:15 000/000 000/000 000/000 000/000
11:30 000/000 000/000 000/000 000/000
11:45 000/000 000/000 000/000 000/000
12:00 000/000 000/000 000/000 000/000
12:15 000/000 000/000 000/000 000/000
12:30 000/000 000/000 000/000 000/000
12:45 000/000 000/000 000/000 000/000
Current 000/000 000/000 000/000 000/000
(P)revious (N)ext (U)pdate
(R)eturn (M)ain Menu
ENTER CHOICE>