ADC Campus-REX2 RS Network Card User Manual


 
Chapter 7 - Using the LCD for Configuration and Management
112 Campus-REX2 RS Interface Card User Manual
Configuring the Alarm
To enable or disable the local Loss of Signal alarm:
1 From the CURRENT ALARMS display, press Next twice. LOCAL I/F
ALARMS CONFIG & STATUS is displayed.
2 Press Enter. The current status of the local alarm is displayed.
3 Press Next. LOC LOSS OF SIG ALM is displayed.
4 Press Enter.
5 Press Next to scroll through the settings for the alarm.
6 Press Enter to select the preferred setting. LOC LOSS OF SIG ALM
is displayed.
Remote Alarms
Loss of Signal (LOS) alarms can occur on the remote unit. This section
describes how to view and configure this alarm.
Viewing Current Alarms
If the CURRENT ALARMS display indicates a remote alarm, you can
determine the alarm type:
1 From the CURRENT ALARMS display, press Next three times. RMT I/F
ALARMS CONFIG & STATUS is displayed.
2 Press Enter. The current status of the remote alarm is displayed.
Configuring the Alarm
To enable or disable the remote Loss of Signal alarm:
1 From the CURRENT ALARMS display, press Next three times. RMT I/F
ALARMS is displayed.
2 Press Enter. The current status of the remote alarm is displayed.
3 Press Next. LOSS OF SIG ALM is displayed.