SETTING THE TIME AND DATE
The time and date parameters provide a common time and date stamp
for system functions such as alarm indications or performance monitoring
histories.
1 To set the time, type then press .
2 At the prompt, type the time in a 24-hour format as shown below then
press .
ENTER NEW TIME (FORMAT HH:MM:SS):
16:34:09
The system displays this new time on System Parameters screen.
3 To set the date, type then press .
4 At the prompt, type two numbers for the day, two number for the month,
and the four-digit year, separated by slashes (/), then press .
ENTER NEW DATE (FORMAT MM/DD/YYYY):
04/30/2003
The system displays this new date on System Parameters screen as
Apr 30, 2003.
System and date take effect immediately after the values are entered and a
save command is not required.
IDENTIFYING THE UNIT AND CIRCUIT
A Campus system supports two different identifiers:
The Unit ID indicates an individual Campus unit which can be either a
desktop unit with an interface card or each interface card and line card
combination in a Campus-Star chassis.
The Circuit ID identifies the HDSL circuit between local and remote
units and is the same for both.
Do the following to set or change these identifiers.
1 From the System Parameters menu, type then press . At the
prompt, enter the Unit ID using a unique identifier up to 32 characters.
Maximum length is 32 characters.
ENTER NEW UNIT ID: Southall Quad 4
1 ENTER
ENTER
2 ENTER
ENTER
3 ENTER