Allied Telesis AT-9400 Switch User Manual


 
Chapter 11: Event Logs and the Syslog Client
214 Section II: Advanced Operations
For example, selecting LOCAL2 as the facility level assigns the
numerical code of 18 to all events sent by the switch to the syslog
server.
13. To include events of a selected severity, type 6 to select Event
Severity.
The following prompt is displayed:
Enter Severity levels to display (ALL, E - Error, W -
Warning, I - Information, D - Debug) ->
The possible options are:
ALL
All messages of the following types are displayed. This is the default.
E - Error
Only error messages are displayed. Error messages indicate that the
switch operation is severely impaired.
W - Warning
Only warning messages are displayed. These messages indicate that
an issue may require manager attention.
I - Information
Only informational messages are displayed. Informational messages
display useful information that you can ignore during normal operation.
D - Debug
Debug messages provide detailed high-volume information that is
intended only for technical support personnel.
You can select more than one severity at a time, separated by a
comma, for example, E,W.
14. To send events generated by a particular AT-S63 software module,
type 7 to select Event Module.
The list of modules is displayed, as shown in Table 1, “AT-S63
Modules” on page 201. The default is All.
20 LOCAL4
21 LOCAL5
22 LOCAL6
23 LOCAL7
Table 4. Numerical Code and Facility Level Mappings (Continued)
Numerical
Code
Facility Level Setting