Allied Telesis AT-9400 Switch User Manual


 
Chapter 21: SNMPv3
378 Section IV: SNMPv3
Use the following format for an IP address:
XXX.XXX.XXX.XXX
7. After making changes, type R until you return to the Main Menu. Then
type S to select Save Configuration Changes.
Modifying the Target Address UDP Port
To modify the Target Address UDP Port parameter in an SNMPv3 Target
Address Table entry, perform the following procedure:
1. Display the Configure SNMPv3 Table menu by performing steps 1
through 3 in “Configuring the SNMPv3 User Table” on page 321. Or,
from the Main Menu type 5->5->5.
The Configure SNMPv3 Table menu is shown in Figure 126 on page
322.
2. From the Configure SNMPv3 Table menu, type 7 to select Configure
SNMPv3 Target Address Table.
The Configure SNMPv3 Target Address Table menu is shown in
Figure 137 on page 373.
3. From the Configure SNMPv3 Target Address Table menu, type 3 to
select Modify SNMPv3 Table Entry.
The Modify SNMPv3 Target Address Table menu is shown in Figure
138 on page 377.
4. To change the Target Address UDP Port, type 2 to select Set Target
Address UDP Port.
The following prompt is displayed:
Enter Target Address Name:
5. Enter a previously configured Target Address Name.
This is the name of the SNMP manager, or host, that manages the
SNMP activity on your switch. You can enter a name of up to 32
alphanumeric characters.
The following prompt is displayed:
Enter UDP Port#: [0 to 65535]-> 162
6. Enter a UDP port.
You can enter a UDP port in the range of 0 to 65,535. The default UDP
port is 162.