Cisco Systems Cisco MGX 8850 Switch User Manual


 
6-38
Cisco MGX 8850 Multiservice Switch Installation and Configuration
Release 1.1.31, Part Number 78-11223-03 Rev. B0, May 2005
Chapter 6 Card and Service Configuration
Configuring Frame Relay Service
CIR Committed information rate (CIR) bps value:
For T1 = in the range 0–1536000
For E1 = in the range 0–2048000.
channel type Value to set type of connection on this channel.
1 = NIW (network interworking)
2 = SIW-transparent (service interworking without any SDU translation)
3 = SIW-translation (service interworking with SDU translation)
4 = FUNI (Frame Relay UNI)
5 = frame forwarding
Connection
Admission Control
(CAC)
This is an optional parameter. You can select one of the following values:
1 = enable
2 = disable (the default)
controller type Value to set signalling controller type as either PVC or SPVC.
1 = PVC (PAR) (default)
2 = SPVC (PNNI)
mastership Value to set status of connection as master or slave.
1 = master
2 = slave (default)
Adm_cntrl Value to enable or disable connection admission control (CAC).
1 = enable CAC
2 = disable CAC (default)