cnfswparms <chan_num> <mastership> <vpcflag> <conn_service_type> (=cos)
<route_priority> <max_cost> <restrict_trunk_type> <pcr> <mcr> <pct_util>
clockmode Clock mode.
1 = synchronous
2 = SRTS
3 = adaptive
IdleSuppEnable Idle suppression, either enabled or disabled.
1 = disable
2 = enable
ForceSuppression External idle suppression, either enabled or disabled.
1 = disable
2 = enable
chan_num Channel (connection) number and is always 32
mastership Current end-point as master or slave: 1 = master; 2 = slave (default)
vpcflag Indicates whether the connection is a VPC or a VCC: 1 = VPC and 2 = VCC
conn_service_type Ttype of service for the connection: 1 = cbr, 2 = vbr, 3 is not used; 4 = ubr, 5 =
atfr; 6 = abrstd, and 7 = abrfst
route_priority Priority of the connection for rerouting. The range is 1–15 and is meaningful only
in relation to the priority of other connections
max_cost Number establishing the maximum cost of the connection route. The range is
1–255 and is meaningful only in relation to the cost of other connections
restrict_trunk_type Number that specifies the type of trunk this connection can traverse. The numbers
are 1 for no restriction, 2 for terrestrial trunk only, and 3 for satellite trunk only
pcr Peak cell rate in cells per second (cps). For T3, the maximum is 118980 cps. For
E3, the maximum is 91405 cps
mcr Minimum cell rate. The range is 1–65535 cells per second