Step 2 Optionally, you can enter cnfcon to modify the connection.
cnfcon <port_num> <CDVT> <CellLossIntegPeriod> <bufsize>
Step 3 Optionally, you can enter cnfswparms on a BPX 8600 series switch to configure connection parameters
for the network segment of a three-segment connection. For a stand-alone application, use whatever
means are supported by the backbone switches.
port_num Port number—always 1
CDVT Tolerable variation for the arrival time of cells. For T3, the range is 125–1447
microseconds in 125-microsecond increments. For E3, the range is 125–1884
microseconds in 125-microsecond increments
CellLossIntegPeriod Amount of time a connection can be in an error condition before an alarm is
declared. The range is 1000–65535 milliseconds
bufsize Egress buffer size in bytes. You can let the CESM compute the size by entering
0 for bufsize or enter the number of bytes up to a maximum of 16224