Compaq AP500 Computer Accessories User Manual


 
4-35
Compaq Professional Workstation AP500 Maintenance and Service Guide
Table 4-28
SCSI Test Error Codes
Error Code Description Recommended Action
XXXX-02 Drive not installed. Check cable connections.
XXXX-03 Media not in drive. Check for and install DATA CD or write-enabled
tape in drive.
XXXX-05 Seek failure Replace the indicated device.
XXXX-06 Drive timed out. Replace the indicated device.
XXXX-07 Drive busy. Replace the indicated device.
XXXX-08 Drive already reserved. Replace the indicated device.
XXXX-09 Unknown
XXXX-10 Unknown
XXXX-11 Media soft error Replace the indicated device.
XXXX-12 Drive not ready. Replace the indicated device.
XXXX-13 Media error Replace the indicated device.
XXXX-14 Drive hardware error Replace the indicated device.
XXXX-15 Illegal drive command Replace the indicated device.
XXXX-16 Media was changed. Replace the indicated device.
XXXX-17 Tape write-protected. 1.Disable write-protect on tape cartridge.
2.Replace tape drive.
XXXX-18 No data detected. Replace the indicated device.
XXXX-21 Drive command aborted. Replace the indicated device.
65XX-24 Media hard error 1.Back up data and perform Surface Analysis to
reallocate defect.
2.Replace drive.
66XX-24 Media hard error 1.Replace current DATA CD with different DATA
CD and attempt to read.
2.Replace drive.
67XX-24 Media hard error 1.Ensure correct media type for this tape drive.
2.Replace current tape with new tape.
3.Replace tape drive.
XXXX-25 Unknown
Continued